@@ -0,0 +1,29 @@
{
"MaxTargetPerOrgan": {
"limit": 2
},
"MaxTargets": {
"limit": 5
},
"MeasurementsLength": [{
"longAxis": 10,
"longAxisSliceThicknessMultiplier": 2,
"modalityIn": ["CT", "MR"],
"locationNotIn": ["Lymph Node"],
"message": "Extranodal lesions must be >= 10mm long axis AND >= double the acquisition slice thickness by CT and MR"
}, {
"shortAxis": 20,
"longAxis": 20,
"modalityIn": ["PX", "XA"],
"locationNotIn": ["Lymph Node"],
"message": "Extranodal lesions must be >= 20mm on chest x-ray (although x-rays rarely used for clinical trial assessment)"
}, {
"shortAxis": 15,
"shortAxisSliceThicknessMultiplier": 2,
"modalityIn": ["CT", "MR"],
"locationIn": ["Lymph Node"],
"message": "Nodal lesions must be >= 15mm short axis AND >= double the acquisition slice thickness by CT and MR"
}],
"NonTargetResponse": {},
"TargetType": {}
}