feat(Calibration Tool): add a calibration tool that can manually recalibrate an image and measurements on it (#3136)
* minor bug fix - reading modalities * react error log fix - button props * react warn fix - Typography color prop * calibration tool without persistence * added toolbar button for calibration tool * icon change for calibration tool * important bug fix for calibration - length and calibration rate calculation * fix weird autocorrection * [fix] bugs after merging upstream * [refactor] conform to the new service names
This commit is contained in:
1 parent
7a36363735
commit
b15988359f
18 files changed
+288
-22
No files matched your search
@@ -24,6 +24,7 @@ The basic viewer comes with the following default measurement tools:
|
||||
- Bidirectional Tool: Creates a measurement of the longest diameter (LD) and longest perpendicular diameter (LPD) in *mm*
|
||||
- Annotation: Used to create a qualitative marker with a freetext label
|
||||
- Ellipse: Measures an elliptical area in *mm<sup>2</sup>* and Hounsfield Units (HU)
|
||||
- Calibration Tool: Calibrate (or override) the Pixel Spacing Attribute (Physical distance in the patient between the center of each pixel, specified by a numeric pair - adjacent row spacing (delimiter) adjacent column spacing in mm)
|
||||
|
||||
When a measurement tool is selected from the toolbar, it becomes the `active` tool. Use the caret to expand the measurement tools and select another tool.
|
||||
<!-- We should add a smaller screenshot for each measurement tool. Maybe have a matrix with 4 identical sized screenshots in a box? Also we should make sure the screenshots have more realistic measurements -->
|
||||
|
||||
@@ -24,6 +24,7 @@ The basic viewer comes with the following default measurement tools:
|
||||
- Bidirectional Tool: Creates a measurement of the longest diameter (LD) and longest perpendicular diameter (LPD) in *mm*
|
||||
- Annotation: Used to create a qualitative marker with a freetext label
|
||||
- Ellipse: Measures an elliptical area in *mm<sup>2</sup>* and Hounsfield Units (HU)
|
||||
- Calibration Tool: Calibrate (or override) the Pixel Spacing Attribute (Physical distance in the patient between the center of each pixel, specified by a numeric pair - adjacent row spacing (delimiter) adjacent column spacing in mm)
|
||||
|
||||
When a measurement tool is selected from the toolbar, it becomes the `active` tool. Use the caret to expand the measurement tools and select another tool.
|
||||
<!-- We should add a smaller screenshot for each measurement tool. Maybe have a matrix with 4 identical sized screenshots in a box? Also we should make sure the screenshots have more realistic measurements -->
|
||||
|
||||
Reference in new issue
Block a user