fix(segmentation): restrict overlay segmentation menu to same frame of reference as viewport background display set (#5900)

- Add FrameOfReferenceUID to SEG and RTSTRUCT displaySet in SOP Class Handlers so the FOR is available for filtering
- Sync optimisticOverlayDisplaySets when background display set changes so the overlay menu reflects the correct state after a background switch
- Add FOR matching guard to the hydrate segmentation synchronizer to prevent the hydration synchronizer from blindly mirroring segmentations from a source viewport to a target viewport if their primary Frames of Reference do not align.
- fix segmentation overlay order reversal on viewport re-render
This commit is contained in:
Ghadeer Albattarni authored and GitHub committed 2026-04-02 08:52:23 -04:00
1 parent a875d7de1f
commit b9029ef6f8
15 files changed
+223 -56

No files matched your search

@@ -22,7 +22,7 @@ export default function getSourceDisplaySet(allDisplaySets, microscopySRDisplayS
const referencedDisplaySet = otherDisplaySets.find(
displaySet =>
displaySet.Modality === 'SM' &&
(displaySet.FrameOfReferenceUID === ReferencedFrameOfReferenceUID ||
(displaySet.frameOfReferenceUID === ReferencedFrameOfReferenceUID ||
// sometimes each depth instance has the different FrameOfReferenceID
displaySet.othersFrameOfReferenceUID.includes(ReferencedFrameOfReferenceUID))
);