import { BaseChecker } from './BaseChecker';
|
|
import { MaxTargetPerOrganCriterion } from '../criteria/MaxTargetPerOrgan';
|
|
import { MaxTargetsCriterion } from '../criteria/MaxTargets';
|
|
import { MeasurementsLengthCriterion } from '../criteria/MeasurementsLength';
|
|
import { ModalityCriterion } from '../criteria/Modality';
|
|
import { NonTargetResponseCriterion } from '../criteria/NonTargetResponse';
|
|
import { TargetTypeCriterion } from '../criteria/TargetType';
|
|
|
|
export class RecistChecker extends BaseChecker {
|
|
|
|
constructor() {
|
|
super();
|
|
|
|
const addCriterion = criterion => this.criteria.push(criterion);
|
|
|
|
addCriterion(new MaxTargetsCriterion(5));
|
|
addCriterion(new MaxTargetPerOrganCriterion(2));
|
|
addCriterion(new ModalityCriterion(this.getModalityOptions()));
|
|
addCriterion(new NonTargetResponseCriterion());
|
|
addCriterion(new TargetTypeCriterion());
|
|
addCriterion(new MeasurementsLengthCriterion(this.getExtranodalLengthOptions()));
|
|
addCriterion(new MeasurementsLengthCriterion(this.getExtranodalXrayLengthOptions()));
|
|
addCriterion(new MeasurementsLengthCriterion(this.getNodalLengthOptions()));
|
|
}
|
|
|
|
getModalityOptions() {
|
|
return {
|
|
method: 'restrict',
|
|
modalities: ['US']
|
|
};
|
|
}
|
|
|
|
getExtranodalLengthOptions() {
|
|
return {
|
|
longAxis: 10,
|
|
longAxisSliceThicknessMultiplier: 2,
|
|
modalityIn: ['CT', 'MR'],
|
|
locationNotIn: ['Lymph Node'],
|
|
message: 'Extranodal lesions must be >= 10mm long axis AND ' +
|
|
'>= double the acquisition slice thickness by CT and MR'
|
|
};
|
|
}
|
|
|
|
getExtranodalXrayLengthOptions() {
|
|
return {
|
|
shortAxis: 20,
|
|
longAxis: 20,
|
|
modalityIn: ['PX', 'XA'],
|
|
locationNotIn: ['Lymph Node'],
|
|
message: 'Extranodal lesions must be >= 20mm on chest x-ray ' +
|
|
'(although x-rays rarely used for clinical trial assessment)'
|
|
};
|
|
}
|
|
|
|
getNodalLengthOptions() {
|
|
return {
|
|
shortAxis: 15,
|
|
shortAxisSliceThicknessMultiplier: 2,
|
|
modalityIn: ['CT', 'MR'],
|
|
locationIn: ['Lymph Node'],
|
|
message: 'Nodal lesions must be >= 15mm short axis AND ' +
|
|
'>= double the acquisition slice thickness by CT and MR'
|
|
};
|
|
}
|
|
|
|
}
|