import { BaseChecker } from './BaseChecker';
import { MaxTargetPerOrganCriterion } from '../criteria/MaxTargetPerOrgan';
import { MaxTargetsCriterion } from '../criteria/MaxTargets';
import { MeasurementsLengthCriterion } from '../criteria/MeasurementsLength';
import { ModalityCriterion } from '../criteria/Modality';
import { NonTargetResponseCriterion } from '../criteria/NonTargetResponse';
import { TargetTypeCriterion } from '../criteria/TargetType';
export class RecistChecker extends BaseChecker {
constructor() {
super();
const addCriterion = criterion => this.criteria.push(criterion);
addCriterion(new MaxTargetsCriterion(5));
addCriterion(new MaxTargetPerOrganCriterion(2));
addCriterion(new ModalityCriterion(this.getModalityOptions()));
addCriterion(new NonTargetResponseCriterion());
addCriterion(new TargetTypeCriterion());
addCriterion(new MeasurementsLengthCriterion(this.getExtranodalLengthOptions()));
addCriterion(new MeasurementsLengthCriterion(this.getExtranodalXrayLengthOptions()));
addCriterion(new MeasurementsLengthCriterion(this.getNodalLengthOptions()));
}
getModalityOptions() {
return {
method: 'restrict',
modalities: ['US']
};
}
getExtranodalLengthOptions() {
return {
longAxis: 10,
longAxisSliceThicknessMultiplier: 2,
modalityIn: ['CT', 'MR'],
locationNotIn: ['Lymph Node'],
message: 'Extranodal lesions must be >= 10mm long axis AND ' +
'>= double the acquisition slice thickness by CT and MR'
};
}
getExtranodalXrayLengthOptions() {
return {
shortAxis: 20,
longAxis: 20,
modalityIn: ['PX', 'XA'],
locationNotIn: ['Lymph Node'],
message: 'Extranodal lesions must be >= 20mm on chest x-ray ' +
'(although x-rays rarely used for clinical trial assessment)'
};
}
getNodalLengthOptions() {
return {
shortAxis: 15,
shortAxisSliceThicknessMultiplier: 2,
modalityIn: ['CT', 'MR'],
locationIn: ['Lymph Node'],
message: 'Nodal lesions must be >= 15mm short axis AND ' +
'>= double the acquisition slice thickness by CT and MR'
};
}
}