[WIP] Hanging Protocol: improving protocol engine to use OHIFError object
This commit is contained in:
parent
638c3df924
commit
6973cd4ec8
@ -207,6 +207,127 @@ Template.viewer.onCreated(() => {
|
||||
});
|
||||
});
|
||||
|
||||
/**
|
||||
* Inits OHIF Hanging Protocol's onReady.
|
||||
* It waits for OHIF Hanging Protocol to be ready to instantiate the ProtocolEngine
|
||||
* Hanging Protocol will use OHIF LayoutManager to render viewports properly
|
||||
*/
|
||||
const initHangingProtocol = () => {
|
||||
// When Hanging Protocol is ready
|
||||
HP.ProtocolStore.onReady(() => {
|
||||
|
||||
// Gets all StudyMetadata objects: necessary for Hanging Protocol to access study metadata
|
||||
const studyMetadataList = OHIF.viewer.StudyMetadataList.all();
|
||||
|
||||
// Caches Layout Manager: Hanging Protocol uses it for layout management according to current protocol
|
||||
const layoutManager = OHIF.viewerbase.layoutManager;
|
||||
|
||||
// Instantiate StudyMetadataSource: necessary for Hanging Protocol to get study metadata
|
||||
const studyMetadataSource = new NucleusStudyMetadataSource();
|
||||
|
||||
// Creates Protocol Engine object with required arguments
|
||||
const ProtocolEngine = new HP.ProtocolEngine(layoutManager, studyMetadataList, [], studyMetadataSource);
|
||||
|
||||
// Sets up Hanging Protocol engine
|
||||
HP.setEngine(ProtocolEngine);
|
||||
});
|
||||
};
|
||||
|
||||
/**
|
||||
* Sets sidebar configuration and active tool based on viewer template instance
|
||||
* @param {Object} instance Template instance for viewer template
|
||||
*/
|
||||
const setActiveToolAndSidebar = instance => {
|
||||
const { studies, currentTimepointId, measurementApi, timepointIds } = instance.data;
|
||||
|
||||
// Default actions for Associated Studies
|
||||
if(currentTimepointId) {
|
||||
// Follow-up studies: same as the first measurement in the table
|
||||
// Baseline studies: target-tool
|
||||
if(studies[0]) {
|
||||
let activeTool;
|
||||
// In follow-ups, get the baseline timepointId
|
||||
const timepointId = timepointIds.find(id => id !== currentTimepointId);
|
||||
|
||||
// Follow-up studies
|
||||
if(studies[0].timepointType === 'followup' && timepointId) {
|
||||
const measurementTools = OHIF.measurements.MeasurementApi.getConfiguration().measurementTools;
|
||||
|
||||
// Create list of measurement tools
|
||||
const measurementTypes = measurementTools.map(
|
||||
tool => {
|
||||
const { id, cornerstoneToolType } = tool;
|
||||
return {
|
||||
id,
|
||||
cornerstoneToolType
|
||||
}
|
||||
}
|
||||
);
|
||||
|
||||
// Iterate over each measurement tool to find the first baseline
|
||||
// measurement. If so, stops the loop and prevent fetching from all
|
||||
// collections
|
||||
measurementTypes.every(({id, cornerstoneToolType}) => {
|
||||
// Get measurement
|
||||
if(measurementApi[id]) {
|
||||
const measurement = measurementApi[id].findOne({ timepointId });
|
||||
|
||||
// Found a measurement, save tool and stop loop
|
||||
if(measurement) {
|
||||
activeTool = cornerstoneToolType;
|
||||
|
||||
return false;
|
||||
}
|
||||
}
|
||||
return true;
|
||||
});
|
||||
}
|
||||
|
||||
// If not set, for associated studies default is target-tool
|
||||
toolManager.setActiveTool(activeTool || 'bidirectional');
|
||||
}
|
||||
|
||||
// Toggle Measurement Table
|
||||
if(instance.data.state) {
|
||||
instance.data.state.set('rightSidebar', 'measurements');
|
||||
}
|
||||
}
|
||||
// Hide as default for single study
|
||||
else {
|
||||
if(instance.data.state) {
|
||||
instance.data.state.set('rightSidebar', null);
|
||||
}
|
||||
}
|
||||
};
|
||||
|
||||
Template.viewer.onRendered(() => {
|
||||
HP.ProtocolStore.onReady(() => {
|
||||
const instance = Template.instance();
|
||||
|
||||
setActiveToolAndSidebar(instance);
|
||||
|
||||
// updateViewports method from current layout manager will be automatically called by the protocol engine;
|
||||
const studyMetadataList = OHIF.viewer.StudyMetadataList.all();
|
||||
const layoutManager = OHIF.viewerbase.layoutManager;
|
||||
|
||||
const studyMetadataSource = new OHIFStudyMetadataSource;
|
||||
ProtocolEngine = new HP.ProtocolEngine(layoutManager, studyMetadataList, [], studyMetadataSource);
|
||||
HP.setEngine(ProtocolEngine);
|
||||
});
|
||||
|
||||
this.autorun(() => {
|
||||
// To make sure ohif viewerMain is rendered before initializing Hanging Protocols
|
||||
const isOHIFViewerMainRendered = Session.get('OHIFViewerMainRendered');
|
||||
|
||||
// To avoid first run
|
||||
if (isOHIFViewerMainRendered) {
|
||||
// To run only when ViewerMainRendered dependency has changed.
|
||||
// because initHangingProtocol can have other reactive components
|
||||
Tracker.nonreactive(initHangingProtocol);
|
||||
}
|
||||
});
|
||||
});
|
||||
|
||||
Template.viewer.helpers({
|
||||
dataSourcesReady() {
|
||||
// TODO: Find a better way to do this
|
||||
|
||||
@ -665,7 +665,8 @@ HP.ProtocolEngine = class ProtocolEngine {
|
||||
}
|
||||
|
||||
if (!currentViewportData.displaySetInstanceUid) {
|
||||
throw new Meteor.Error('No matching display set found?');
|
||||
//@TODO: make OHIFError use Meteor.Error instead of simple Error()
|
||||
throw new OHIF.viewerbase.OHIFError('ProtocolEngine::updateViewports No matching display set found?');
|
||||
}
|
||||
|
||||
viewportData.push(currentViewportData);
|
||||
|
||||
@ -33,84 +33,6 @@ Template.viewerMain.onRendered(() => {
|
||||
|
||||
OHIF.viewerbase.layoutManager = new LayoutManager(parentElement, studies);
|
||||
|
||||
// @TODO: move this logic to the viewers to break dependency of ohif-hanging-protocols package and avoid circurlar dependencies
|
||||
// HP.ProtocolStore.onReady(() => {
|
||||
// const { studies, currentTimepointId, measurementApi, timepointIds } = instance.data;
|
||||
|
||||
// // Default actions for Associated Studies
|
||||
// if(currentTimepointId) {
|
||||
// // Follow-up studies: same as the first measurement in the table
|
||||
// // Baseline studies: target-tool
|
||||
// if(studies[0]) {
|
||||
// let activeTool;
|
||||
// // In follow-ups, get the baseline timepointId
|
||||
// const timepointId = timepointIds.find(id => id !== currentTimepointId);
|
||||
|
||||
// // Follow-up studies
|
||||
// if(studies[0].timepointType === 'followup' && timepointId) {
|
||||
// const measurementTools = OHIF.measurements.MeasurementApi.getConfiguration().measurementTools;
|
||||
|
||||
// // Create list of measurement tools
|
||||
// const measurementTypes = measurementTools.map(
|
||||
// tool => {
|
||||
// const { id, cornerstoneToolType } = tool;
|
||||
// return {
|
||||
// id,
|
||||
// cornerstoneToolType
|
||||
// }
|
||||
// }
|
||||
// );
|
||||
|
||||
// // Iterate over each measurment tool to find the first baseline
|
||||
// // measurment. If so, stops the loop and prevent fetching from all
|
||||
// // collections
|
||||
// measurementTypes.every(({id, cornerstoneToolType}) => {
|
||||
// // Get measurement
|
||||
// if(measurementApi[id]) {
|
||||
// const measurement = measurementApi[id].findOne({ timepointId });
|
||||
|
||||
// // Found a measurement, save tool and stop loop
|
||||
// if(measurement) {
|
||||
// activeTool = cornerstoneToolType;
|
||||
|
||||
// return false;
|
||||
// }
|
||||
// }
|
||||
// return true;
|
||||
// });
|
||||
// }
|
||||
|
||||
// // If not set, for associated studies default is target-tool
|
||||
// toolManager.setActiveTool(activeTool || 'bidirectional');
|
||||
// }
|
||||
|
||||
// // Toggle Measurement Table
|
||||
// if(instance.data.state) {
|
||||
// instance.data.state.set('rightSidebar', 'measurements');
|
||||
// }
|
||||
// }
|
||||
// // Hide as default for single study
|
||||
// else {
|
||||
// if(instance.data.state) {
|
||||
// instance.data.state.set('rightSidebar', null);
|
||||
// }
|
||||
// }
|
||||
|
||||
// if (OHIF.viewer.isProtocolEngineDisabled === true) {
|
||||
// OHIF.viewerbase.layoutManager.updateViewports();
|
||||
// } else {
|
||||
// // updateViewports method from current layout manager will be automatically called by the protocol engine;
|
||||
// const studyMetadataList = OHIF.viewer.StudyMetadataList.all();
|
||||
// const layoutManager = OHIF.viewerbase.layoutManager;
|
||||
|
||||
// const studyMetadataSource = new NucleusStudyMetadataSource;
|
||||
// ProtocolEngine = new HP.ProtocolEngine(layoutManager, studyMetadataList, [], studyMetadataSource);
|
||||
// HP.setEngine(ProtocolEngine);
|
||||
// }
|
||||
|
||||
// Session.set('ViewerMainReady', Random.id());
|
||||
// });
|
||||
|
||||
// Enable hotkeys
|
||||
hotkeyUtils.enableHotkeys();
|
||||
|
||||
|
||||
Loading…
Reference in New Issue
Block a user