* fix(Measurement): fixed line dashing of measurements in various scenarios
For a StackViewport simply rely on the SeriesInstanceUID being part of the
tracked measurements or not.
For a VolumeViewport first check the image id of the current image in the viewport
and then check the SeriesInstanceUID (like for a StackViewport) if an id is returned.
To reliably get the id of the current image, listen for the VOLUME_VIEWPORT_NEW_VOLUME event.
* Changes for PR comments.
* fix: KO series being displayed in browser list
* fix sr for volume viewports
* move highlight labelmap to RAF
* remove commented code
* fix the hydration bug for the SR
* apply review comments
* revert the key images for sr
* Remove some obsolete changes
* set initial image for sr instead of jump
* Remove viewportType stack
---------
Co-authored-by: Alireza <ar.sedghi@gmail.com>
* fix: multiframe
* fix the unnecessary use of prior since some servers dont like it
* add authentication via token in url
* add data citation
* add resources
* upgrade packages
* yarn lock
* apply review comments
* fix: Jump to measurement after presentation store
* Fix initial load of DICOM SR
* Fix measurement highlight issues
* Clear measurements changed to array
* Fix merge issues
* PR comments
* Removed unused formatting. Change to single event
* Fix the unit test
* PR review comments
* refactor(viewport): simplify imports, align destructuring
Simplify import statements by removing unused imports, organize existing imports, and align destructured imports consistently across the component.
---------
* fix: viewportdialoge not appearing in non-tracked viewports
* feat(viewports): Introduce useViewportDialog and remove deprecated API
This commit introduces the `useViewportDialog` hook and replaces the deprecated `viewportDialogApi` with the new `viewportDialogState`. Additionally, the notifications in `OHIFCornerstoneRTViewport` and `OHIFCornerstoneViewport` have been removed. Finally, the `CinePlayer` component now accepts optional parameters.
* fix tests
* feat: initial RT support
* make the segmentation service work with representation data
* feat: make segmentation service work with representations
* fix rtss vis
* fix: rt hydration
* fix the rendering of rt names
* fix imports
* refactor: Modify status and click handling for hydration of RTStructures
Modify status and click handling for hydration of RTStructures by renaming `onPillClick` to `onStatusClick` in `OHIFCornerstoneRTViewport.tsx` and `_getStatusComponent.tsx` files. Also, update initial segmentation configurations in `PanelSegmentation.tsx` and simplify configuration changes and values for segmentation service in `SegmentationService.ts`. Finally, remove console debug in `CornerstoneViewportService.ts`.
* wip for highlighting contours
* refactor rt displayset code
* review code update
* update cornerstone dependencies
* refactor: Update license year, version number, and minor code cleanup
This commit updates the license year in several files, updates the version number in package.json, and contains minor code cleanup in two files.
* add bulkdataURI retrieve for RT
* fix package version
* apply review comments
* apply review comments
* apply review comments
* feat(panels): refactor and streamline segmentation configuration and inputs
Rewrote state hooks and streamlined the configuration input for `PanelSegmentation` to be more verbose and reusable. Included several new input types, including the `InputRange` component which now shows a fixed floating value based on the step provided. The `SegmentationConfig` component now works with dynamic values controlled by `initialConfig`. These changes should improve function usability and make the code more maintainable going forward.
* fix various bugs
* fix contour delete by upgrade cs3d version
* feat(viewport, inputNumber, segmentationConfig, orthanc): Implement minimum and maximum values for input number components, and useBulkDataURI for Orthanc configuration. Compare measurement view planes with absolute viewport view planes in Cornerstone viewport.
* update yarn lock
* fix: Make the cornerstone sR viewport show all measurements
* PR fixes
* PR fixes
* Add a DICOM SR hanging protocol
* Duplicate the hanging protocol for seg as well
* PR requested change
* PR requested changes
* PR fixes plus merge update fixes
* PR fixes and integration test fix
* PR - documentation
* Use more consistent type/structure for services
* Fix restoring SR so the tests described work
* One more typed service
* Added types for the Cornerstone library
* Couple more type fixes
* fix(Volume3DViewport) - Replacing the volume 3D viewport with another reconstructable series fails
- updated cornerstone3D core package dependency
- checked for null presentations when setting presentations
- added viewportIndex as a dependency for enabling and disabling an OHIFCornerstoneViewport
* PR feedback - removed viewportIndex useEffect dependency for enabling/disabling OHIFCornerstoneViewport
* feat: Allow customizing the measurements panel.
Also includes default display of the site/finding values from the DICOM
SR object.
Update fixes
PR review comments - move the recordInteraction to COmmandsManager.run
PR fixes
fix: Dependency updates to allow right click to be recognized
PR fixes
* Use newer CSWIL
* Make both the base measurements and the tracking measurements show codes
* Fix the right click context menu bringing up menu