* fix: Detect 16 bit when 8 declared
* Update bun lock with dcmjs changes
* PR comments
* Update package versions
* fix: Palette color lookup table data for dcmjs parsed data
* fix: Published version should match (#5813)
* fix: Published version should match
* Move version number update to package.json
* fix: Netlify version number update
* Try updating platform app vesion too
* PR comments
---------
Co-authored-by: Joe Boccanfuso <109477394+jbocce@users.noreply.github.com>
* Update latest cs3d
* formatting
* fix: Use 64k instead of 0 for number of entries
* fix: Revert CS3D version to see test issues
* Updated screenshots for ArrowAnnotate.spec.ts.
* Update CS3D version
* fix: Update cs3d 4.17.4
* Update bun lock
* Update bun
* Downgrade to CS3D 4.17.2 to try to release
---------
Co-authored-by: Joe Boccanfuso <109477394+jbocce@users.noreply.github.com>
Co-authored-by: Joe Boccanfuso <joe.boccanfuso@radicalimaging.com>
* fix: Published version should match
* Move version number update to package.json
* fix: Netlify version number update
* Try updating platform app vesion too
* PR comments
---------
Co-authored-by: Joe Boccanfuso <109477394+jbocce@users.noreply.github.com>
Will address a few more comments in a separate PR released after this one into 3.13
* fix(HistoryMemo): Segmentation delete wasn't remembered
* Temporary add of package.json linking
* fix: Use newer dcmjs version and delete segmentation with history cs3d
* fix: Initial sort not consistent
* Add better sort criteria
* Remove sorting changes
* Start replacing screen shots
* Update bun lock for version
* Leave default sort for test mode
* fix: Add consistent sorting for same series splits
* PR comments
* docs: add notes for series/display set sort
* Updated example docs
* Update sortVector to be compareSameStudy
* Add unit test
* PR comments
Note: FOSSA check is invalid, but we don't have the ignore FOSSA version included.
* fix: sculptor tool fixes
* Add yarn
* update vtk.js version as well to match
* [WIP] Fix contour annotations RTSS saving
* fix: Export image sop image reference provider
* Fixes for download with filename
* Updates to fix metadata issues with CS3D
* Updates to save menu
* Fixing some additional re-save metadata
* Add support for saving with predecessor image sequence
* PR comment fixes
* fix: Load RTSS after save
* fix segmentation save
* fix load of mixed seg/rt studies
* Use frame module to get information on the frame shown
* Fix study browser to use instances.length when numImageFrames not present
* fix: Load of display set split from multiple non-FOR referenes
* Fix RT and SEG applying to wrong series because of using
referenced series sequence without checkout sop instances
* Fix save seg
* Update to released CS3D versions
* test: Add revokeObjectURL to test download blob
* Add hard dependency on mode-basic to fix build order issues
* fix: build
* Try to fix build segmentation
* PR comments
* PR comment update
This change makes the OHIF side consistent with the CS3D user calibration settings, and will correctly display px and rounding values consistent with the CS3D display.
There are a couple of changes here which should improve stability of the tests. Hopefully that will be sufficient, but it is difficult to tell for sure if it is complete.
* fix: KO series being displayed in browser list
* fix sr for volume viewports
* move highlight labelmap to RAF
* remove commented code
* fix the hydration bug for the SR
* apply review comments
* revert the key images for sr
* Remove some obsolete changes
* set initial image for sr instead of jump
* Remove viewportType stack
---------
Co-authored-by: Alireza <ar.sedghi@gmail.com>
* fix: Jump to measurement after presentation store
* Fix initial load of DICOM SR
* Fix measurement highlight issues
* Clear measurements changed to array
* Fix merge issues
* PR comments
* Removed unused formatting. Change to single event
* Fix the unit test
* PR review comments
* refactor(viewport): simplify imports, align destructuring
Simplify import statements by removing unused imports, organize existing imports, and align destructured imports consistently across the component.
---------
* fix: Make the cornerstone sR viewport show all measurements
* PR fixes
* PR fixes
* Add a DICOM SR hanging protocol
* Duplicate the hanging protocol for seg as well
* PR requested change
* PR requested changes
* PR fixes plus merge update fixes
* PR fixes and integration test fix
* PR - documentation
* feat: Add a new hanging protocol @ohif/mn
* Add @ohif/seg example
* PR comments and a couple more fixes to make things cleaner
* PR comment
* Added an example to cause the PR checks to rerun
* Use more consistent type/structure for services
* Fix restoring SR so the tests described work
* One more typed service
* Added types for the Cornerstone library
* Couple more type fixes
* feat: Allow navigating to a specified series and sop instance
This was a feature in OHIF v2, so adding it to v3, albeit with new
parameters.
feat: Allow comma separated as well as repeated args params
* docs
* Test fixes
* feat: Navigate to SOP selected - PR fixes
* Updated docs
* PR fixes
* fix: The display of linked viewports during drag and drop has a race
* PR review comments
* fix: Segmentation display two up
* Removing console logs
* Fix the blank viewport can have stuff added to it
* Fix the null name on HP module
* Fix the navigate to initial image
* Fix the nth interleave loader
* Fix the unit tests
* PR comments - docs mostly
* fix: Exception thrown on change displayset after double click
* feat: Allow customizing the measurements panel.
Also includes default display of the site/finding values from the DICOM
SR object.
Update fixes
PR review comments - move the recordInteraction to COmmandsManager.run
PR fixes
fix: Dependency updates to allow right click to be recognized
PR fixes
* Use newer CSWIL
* Make both the base measurements and the tracking measurements show codes
* Fix the right click context menu bringing up menu
* feat: Context menu
feat: Custom context menu
Adding documentation
PR updates
* fix: Capture tool exception
* PR updates
* Add fully worked out examples in the basic test mode/extension
* Fix the menu display
* fix: Make the commands on clicks much more configurable
* Wait for load before double clicking
* docs
* PR changes - nothing functional, just moving things endlessly
* PR comments
* PR changes - rename the default context menu
* Renamed the cornerstoneContextMenu to measurementsContextMenu
* Add chevron right to the sub-menus
* fix: Some residual issues with hanging protocol after state sync
fix: Some issues introduced by the state syncing changes
* fix: PR fixes, mostly code cleanup
* Improve a race condition in an automated test
* Remove obsolete code
* PR fixes
* feat: Add state sync and use it to remember viewport grid info
fix: Version updates
Fixes for toggling MPR mode
Fix the display when the interleaved load module fails
Fix the memory of the state to restore correctly
PR fixes for the state sync service
PR fixes
PR fixes
PR fixes
Added a hack warning to remove volumeDeactivate
Fixes for TMTV colormap setting
Fix the casing
Missed renames
fix: tests not running due to variance in ordering
Reverting some fixes to change case
PR changes - mostly comments and minor improvements
fix: All display sets were being updated on drag and drop
PR fixes - mostly renames
PR fixes
Test support for OHIF, for HP branch
test: Add at least a minimal set of automated tests for hanging protocols
Docs
PR fixes
Merge fixes
DOCS updates
Add an example of the mn hanging protocol
PR fixes
PR fixes
PR fixes
* Fix the drag and drop
PR fixes
* PR changes - update default keys for next/previous stage
* fix: Was storing the custom viewport grid too aggressively
Caused by a PR change misspelling a variable
* fix(misc):Update the data source name, provide a /datasources
Update the imports for a few things to match, to avoid 2 versions
Fix the datasources name
pr:Make the data source selector configurable
* Updated data source selector page as requested
* PR fixes